Home
/
Mastercool 93661-MB 2-Way Manifold Gauge Set 80mm R134a/R404A 3×150cm
Mastercool 93661-MB 2-Way Manifold Gauge Set 80mm R134a/R404A 3×150cm
305
sold
Quantity
-
Detail
Mastercool 93661-MB 2-Way Aluminium Manifold Gauge Set 80mm R134a/R404A 3×150cm
A professional 2-way aluminium manifold gauge set from Mastercool — the leading manufacturer of professional quality A/C manifold gauge sets. Constructed of the finest materials and machined with precision to the highest quality standards, every Mastercool manifold is built to last.
Key Features
- Free-Floating Piston Valves — less wear and tear compared to market-standard twisting piston valves; longer service life
- Double O-Ring Seal — superior seal for fewer leaks and more reliable operation
- Class 1.6 Accuracy, 80mm Gauges — large, colour-coordinated dials for easy refrigerant recognition and accurate readings
- Factory Calibrated — gauges correctly calibrated before shipment; field recalibration is possible via adjusting the screw on gauge face
- 3×150cm Standard Hoses — 1/4" SAE connections; blue low-side, red high-side, yellow centre
- Depressor Fittings — built-in depressors pierce Schrader valve cores on connection
Technical Specifications
- Model: 93661-MB
- Gauge Size: 80mm
- Gauge Class: 1.6
- Gauge Part Numbers: MBH (high side), MBL (low side)
- Manifold Body: Aluminium
- Valve Type: Free-floating piston
- Refrigerants: R134a, R404A, R407C, R22, R507A
- Hose Length: 3×150cm standard hoses
- Connections: 1/4" SAE
- Country of Origin: USA
Replaceable Parts
- 85215 — O-Rings (4 pcs)
- 85216 — Seal and Seat Assembly (2 pcs)
Related Manifolds Available from Airconspares
- 92661-MB-E — Same gauges, 3×150cm ball valve end hoses
- 96261-MB-40360 — 4-Way version, 80mm R134a/R404A 3×150cm
- 96261-MB-E — 4-Way version, 80mm 3/8" bore 3×150cm
- 89772-MB — 2-Way automotive A/C manifold, 80mm R134a 3×180cm
Pre-Service Instructions
- Close both valves by turning the high and low knobs clockwise before connecting
- Connect the red (high) hose to the high port and the blue (low) hose to the low port
- If using adapters, ensure they are fully tightened and piercing the access valve
Important Notes
- A system found to be low on refrigerant as a result of a leak must be fully evacuated before recharging
- If charging on the liquid or high side, use only the high side valve — keep the low side valve closed
- After testing, always use a recovery machine to evacuate refrigerant remaining in hoses or the manifold